Abstract
For the past few decades, lithium-ion batteries (LIBs) have gained popularity and have
become a technology of choice for the automotive industry, owing to their high power and
energy density. However, LIBs suffer degradation during operation i.e. (dis)charge cycling
and at extreme temperatures. This degradation leads to irreversible physical and chemical
changes, eventually affecting the electrical properties causing capacity deterioration and a rise
in internal resistance. Due to sluggish electrochemical reactions low-temperature operation is
considered to be a hindering factor for the efficient working of batteries. This thesis aims to
deepen the knowledge and understanding of battery degradation under multiple operating
conditions i.e. temperature (low), C-rate, and SOC. Batteries being inherently non-linear and
time-variant, it is demonstrated here that NFRA/harmonic analysis reveals highly non-linear
dynamic behaviour of batteries for degradation diagnosis.
The first part explores the applicability of EIS (electrochemical impedance spectroscopy) for
battery characterization under low temperatures and multiple SOCs. The study highlights the
major parameters from EIS/DRT that are most influenced by low temperature i.e. charge
transfer resistance (RCT), peak height/intensity (DRT), and shift in time constant from DRT
(fr). The aforementioned parameters are then used to infer battery temperature based on the
Arrhenius relation. Overall, a single-order polynomial model estimated a temperature of
+<3°C for all the studied SOCs. After verifying the model with 5 new cells, it was concluded
that among all three features peak height (DRT) gave the lowest RMSE i.e. on average of
+1.77°C. It is considered that DRT might be a better choice for sensorless temperature
measurement for being a model-independent approach as compared to equivalent circuit
modeling (ECM).
The second part emphasizes applying NFRA (high amplitude AC signal=2C) under multiple
SOCs to detect capacity fade. This study investigates the effect of temperature and SOC (state
of charge) on harmonic measurements. The dependence of harmonics on SOC is done on
commercial 21700 cells at various open circuit voltages (OCVs). As an indicator of capacity
deterioration, THD% (total harmonic distortion) is found to correlate with state-of-health
(SOH) under all OCVs. THD% is highly SOC dependent for frequencies <10 Hz, 0.8%-9%
of THD for low OCVs (2.75V, 2.9V, and 3.2V) and <0.3% for high OCVs (3.5V, 3.8V, and
4.1V). Although the ageing trend i.e. high THD for aged cells, is inconsistent for <10Hz, this
trend becomes consistent in a particular frequency range of 10 Hz-150 Hz for all OCVs.
Furthermore, NFRA was able to distinguish different aging pathways in a similar range i.e.
higher THD% response for cell aged at 0°C in comparison to one aged at 25°C. Generally,
NFRA has proven to be a powerful method for battery diagnostics by analysing and
distinguishing different aging mechanisms. This serves as a preliminary study into SOC
dependence and aging pathway and can thus support second-life usage of batteries and help
in minimizing environmental impact and extend the value chain.
In the final part of the thesis, a non-invasive real-time lithium plating detection method based
on harmonic analysis is proposed for the first time here. A commercial NMC811 21700
(1C=4.9Ah) is subjected to fast charge at a low temperature(0°C) to deliberately induce
plating. A low amplitude (C/20) AC perturbation is also applied on top of DC charging to
continuously measure the harmonic response (THD%) from full discharge to fully charge
state. After detailed experimentations, it is observed that frequency range of 100 Hz-180 Hz
correspond with plating detection, i.e. charging (DC) at 0°C with 175Hz AC perturbation, an
increase of THD% from 0%SOC to 100% SOC is observed to be 5.12%, 3.51% and 2.94%
for DC current of 2C,1C and 0.3C respectively. However, a gradual monotonic increase in
THD% during charge is observed for all C-rates but it is higher for 2C i.e. THD at 0%SOC is
9% which increased to 14% at 100% SOC, possibly due to high over-potential. The method
was further verified by differential voltage analysis (DVA) and distribution of relaxation
times (DRT). Limitations of harmonic analysis for real-time plating detection are identified
based on multiple temperatures, optimum choice of AC amplitude and frequency, and internal
rise of temperature. Overall, the proposed method gives an insight into the potential of
harmonic analysis for its applicability during charging for fault diagnosis. The study has left
avenues for further studies and strengthen the concepts of non-linear analysis in the field of
commercial lithium-ion batteries. This can help in implementing an early warning on-board
real-time diagnosis tool thus improving and encouraging safe fast charging under cold
conditions
| Date of Award | 2024 |
|---|---|
| Original language | English |
| Awarding Institution |
|
| Sponsors | FEV UK Ltd |
| Supervisor | Oliver Curnick (Supervisor), Taz Amietszajew (Supervisor) & Chitta Saha (Supervisor) |
Cite this
- Standard