Towards the Development of a Full Motion FES Rowing with Accurate Ergometry: RowStim IV

Brian Andrews, Robin Gibbons, Simon Goodey, Adrian Poulton, James Shippen

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

A novel FES rowing system is presented that facilitates a near normal rowing style. The system is presently based on the Concept2 ergometer. Here we present an error analysis the C2 performance monitor which suggests that a more accurate monitor will be required for medal placement in competitive rowing events.
Original languageEnglish
Title of host publicationConverging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018
Place of PublicationCham
PublisherSpringer Nature
Pages917-921
Number of pages5
ISBN (Electronic)978-3-030-01845-0
ISBN (Print)978-3-030-01844-3
DOIs
Publication statusPublished - 2018
Event4th International Conference on NeuroRehabilitation - Pisa, Italy
Duration: 16 Oct 201820 Oct 2018
Conference number: 4th
http://www.icnr2018.org/

Publication series

NameBiosystems & Biorobotics
Volume21

Conference

Conference4th International Conference on NeuroRehabilitation
Abbreviated titleICNR2018
CountryItaly
CityPisa
Period16/10/1820/10/18
Internet address

Fingerprint

Exercise equipment
Error analysis

Cite this

Andrews, B., Gibbons, R., Goodey, S., Poulton, A., & Shippen, J. (2018). Towards the Development of a Full Motion FES Rowing with Accurate Ergometry: RowStim IV. In Converging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018 (pp. 917-921). (Biosystems & Biorobotics ; Vol. 21). Cham: Springer Nature. https://doi.org/10.1007/978-3-030-01845-0_184

Towards the Development of a Full Motion FES Rowing with Accurate Ergometry : RowStim IV. / Andrews, Brian; Gibbons, Robin; Goodey, Simon; Poulton, Adrian; Shippen, James.

Converging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018 . Cham : Springer Nature, 2018. p. 917-921 (Biosystems & Biorobotics ; Vol. 21).

Research output: Chapter in Book/Report/Conference proceedingChapter

Andrews, B, Gibbons, R, Goodey, S, Poulton, A & Shippen, J 2018, Towards the Development of a Full Motion FES Rowing with Accurate Ergometry: RowStim IV. in Converging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018 . Biosystems & Biorobotics , vol. 21, Springer Nature, Cham, pp. 917-921, 4th International Conference on NeuroRehabilitation , Pisa, Italy, 16/10/18. https://doi.org/10.1007/978-3-030-01845-0_184
Andrews B, Gibbons R, Goodey S, Poulton A, Shippen J. Towards the Development of a Full Motion FES Rowing with Accurate Ergometry: RowStim IV. In Converging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018 . Cham: Springer Nature. 2018. p. 917-921. (Biosystems & Biorobotics ). https://doi.org/10.1007/978-3-030-01845-0_184
Andrews, Brian ; Gibbons, Robin ; Goodey, Simon ; Poulton, Adrian ; Shippen, James. / Towards the Development of a Full Motion FES Rowing with Accurate Ergometry : RowStim IV. Converging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018 . Cham : Springer Nature, 2018. pp. 917-921 (Biosystems & Biorobotics ).
@inbook{331f1f0921514c7ebec4807970e9eca9,
title = "Towards the Development of a Full Motion FES Rowing with Accurate Ergometry: RowStim IV",
abstract = "A novel FES rowing system is presented that facilitates a near normal rowing style. The system is presently based on the Concept2 ergometer. Here we present an error analysis the C2 performance monitor which suggests that a more accurate monitor will be required for medal placement in competitive rowing events.",
author = "Brian Andrews and Robin Gibbons and Simon Goodey and Adrian Poulton and James Shippen",
year = "2018",
doi = "10.1007/978-3-030-01845-0_184",
language = "English",
isbn = "978-3-030-01844-3",
series = "Biosystems & Biorobotics",
publisher = "Springer Nature",
pages = "917--921",
booktitle = "Converging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018",

}

TY - CHAP

T1 - Towards the Development of a Full Motion FES Rowing with Accurate Ergometry

T2 - RowStim IV

AU - Andrews, Brian

AU - Gibbons, Robin

AU - Goodey, Simon

AU - Poulton, Adrian

AU - Shippen, James

PY - 2018

Y1 - 2018

N2 - A novel FES rowing system is presented that facilitates a near normal rowing style. The system is presently based on the Concept2 ergometer. Here we present an error analysis the C2 performance monitor which suggests that a more accurate monitor will be required for medal placement in competitive rowing events.

AB - A novel FES rowing system is presented that facilitates a near normal rowing style. The system is presently based on the Concept2 ergometer. Here we present an error analysis the C2 performance monitor which suggests that a more accurate monitor will be required for medal placement in competitive rowing events.

U2 - 10.1007/978-3-030-01845-0_184

DO - 10.1007/978-3-030-01845-0_184

M3 - Chapter

SN - 978-3-030-01844-3

T3 - Biosystems & Biorobotics

SP - 917

EP - 921

BT - Converging Clinical and Engineering Research on Neurorehabilitation III. ICNR 2018

PB - Springer Nature

CY - Cham

ER -