The Effect of hollow sphered structure on stress shielding reduction

Mahshid Yazdi Far, Ibrahim Esat, Mohammadreza Yazdifar

Research output: Contribution to journalArticle

8 Downloads (Pure)

Abstract

Bone mechanics and traditional implant materials cause a frequent problem for patients of total hip arthroplasty (THA): the bone becomes shielded from the loading. This will result in loosening of the implant, pain, and therefore revision surgery will take place to correct the issue. The current study, a methodology is developed for creating an innovative structural design that extracts volume in the shape of spheres from the samples, in order to focus solely on expected behaviour within the samples and bone. The design decreases extreme stresses carried by samples and pass them onto the remaining bone. Finite element analysis was applied to various models with different complex internal structures that contain hollow spheres close to surface. Moreover, compression test was applied to solid sample and the experimental case containing hollow spheres. This approach was to investigate the effects of spherical hollow structure near the side surface and its bonesample interface. The models containing hollow spheres have smaller young modulus and strength in comparison to the solid sample. The hollow spherical structures reduce the stress shielding and they transfer more stress onto the bone compared to the solid model. This approach also re-structures a hard material such as stainless steel to enhance osseointegration. The reduction of the young modulus and stress directly depends on the volume of the spheres in the models. However, there is a range defined for the volume that could could be extracted from solid structure to achieve the most effective outcome.
Original languageEnglish
Pages (from-to)16-25
Number of pages11
JournalEuropean Scientific Journal (ESJ)
Volume14
Issue number6
DOIs
Publication statusPublished - 2018

Fingerprint

Shielding
Bone
Elastic moduli
Arthroplasty
Structural design
Surgery
Mechanics
Compaction
Stainless steel
Finite element method

Bibliographical note

ESJ articles are published under the Creative Commons Attribution License.

Cite this

The Effect of hollow sphered structure on stress shielding reduction. / Yazdi Far, Mahshid; Esat, Ibrahim; Yazdifar, Mohammadreza.

In: European Scientific Journal (ESJ), Vol. 14, No. 6, 2018, p. 16-25.

Research output: Contribution to journalArticle

Yazdi Far, Mahshid ; Esat, Ibrahim ; Yazdifar, Mohammadreza. / The Effect of hollow sphered structure on stress shielding reduction. In: European Scientific Journal (ESJ). 2018 ; Vol. 14, No. 6. pp. 16-25.
@article{b89e6c2b4fd040b1b527cbe2613ccd52,
title = "The Effect of hollow sphered structure on stress shielding reduction",
abstract = "Bone mechanics and traditional implant materials cause a frequent problem for patients of total hip arthroplasty (THA): the bone becomes shielded from the loading. This will result in loosening of the implant, pain, and therefore revision surgery will take place to correct the issue. The current study, a methodology is developed for creating an innovative structural design that extracts volume in the shape of spheres from the samples, in order to focus solely on expected behaviour within the samples and bone. The design decreases extreme stresses carried by samples and pass them onto the remaining bone. Finite element analysis was applied to various models with different complex internal structures that contain hollow spheres close to surface. Moreover, compression test was applied to solid sample and the experimental case containing hollow spheres. This approach was to investigate the effects of spherical hollow structure near the side surface and its bonesample interface. The models containing hollow spheres have smaller young modulus and strength in comparison to the solid sample. The hollow spherical structures reduce the stress shielding and they transfer more stress onto the bone compared to the solid model. This approach also re-structures a hard material such as stainless steel to enhance osseointegration. The reduction of the young modulus and stress directly depends on the volume of the spheres in the models. However, there is a range defined for the volume that could could be extracted from solid structure to achieve the most effective outcome.",
author = "{Yazdi Far}, Mahshid and Ibrahim Esat and Mohammadreza Yazdifar",
note = "ESJ articles are published under the Creative Commons Attribution License.",
year = "2018",
doi = "10.19044/esj.2018.v14n6p16",
language = "English",
volume = "14",
pages = "16--25",
journal = "European Scientific Journal",
issn = "1857-7881",
publisher = "European Scientific Institute",
number = "6",

}

TY - JOUR

T1 - The Effect of hollow sphered structure on stress shielding reduction

AU - Yazdi Far, Mahshid

AU - Esat, Ibrahim

AU - Yazdifar, Mohammadreza

N1 - ESJ articles are published under the Creative Commons Attribution License.

PY - 2018

Y1 - 2018

N2 - Bone mechanics and traditional implant materials cause a frequent problem for patients of total hip arthroplasty (THA): the bone becomes shielded from the loading. This will result in loosening of the implant, pain, and therefore revision surgery will take place to correct the issue. The current study, a methodology is developed for creating an innovative structural design that extracts volume in the shape of spheres from the samples, in order to focus solely on expected behaviour within the samples and bone. The design decreases extreme stresses carried by samples and pass them onto the remaining bone. Finite element analysis was applied to various models with different complex internal structures that contain hollow spheres close to surface. Moreover, compression test was applied to solid sample and the experimental case containing hollow spheres. This approach was to investigate the effects of spherical hollow structure near the side surface and its bonesample interface. The models containing hollow spheres have smaller young modulus and strength in comparison to the solid sample. The hollow spherical structures reduce the stress shielding and they transfer more stress onto the bone compared to the solid model. This approach also re-structures a hard material such as stainless steel to enhance osseointegration. The reduction of the young modulus and stress directly depends on the volume of the spheres in the models. However, there is a range defined for the volume that could could be extracted from solid structure to achieve the most effective outcome.

AB - Bone mechanics and traditional implant materials cause a frequent problem for patients of total hip arthroplasty (THA): the bone becomes shielded from the loading. This will result in loosening of the implant, pain, and therefore revision surgery will take place to correct the issue. The current study, a methodology is developed for creating an innovative structural design that extracts volume in the shape of spheres from the samples, in order to focus solely on expected behaviour within the samples and bone. The design decreases extreme stresses carried by samples and pass them onto the remaining bone. Finite element analysis was applied to various models with different complex internal structures that contain hollow spheres close to surface. Moreover, compression test was applied to solid sample and the experimental case containing hollow spheres. This approach was to investigate the effects of spherical hollow structure near the side surface and its bonesample interface. The models containing hollow spheres have smaller young modulus and strength in comparison to the solid sample. The hollow spherical structures reduce the stress shielding and they transfer more stress onto the bone compared to the solid model. This approach also re-structures a hard material such as stainless steel to enhance osseointegration. The reduction of the young modulus and stress directly depends on the volume of the spheres in the models. However, there is a range defined for the volume that could could be extracted from solid structure to achieve the most effective outcome.

U2 - 10.19044/esj.2018.v14n6p16

DO - 10.19044/esj.2018.v14n6p16

M3 - Article

VL - 14

SP - 16

EP - 25

JO - European Scientific Journal

JF - European Scientific Journal

SN - 1857-7881

IS - 6