Abstract

The resolution characteristics of intensity modulated beam (IMB) profiles produced by milled compensators and by multileaf collimators (MLCs) are independently investigated with respect to the primary fluence. It is shown that both methods have different characteristics in the longitudinal and lateral direction and, as a consequence, the resolutions of the longitudinal and lateral delivered IMB profiles differ. For both methods, the restrictions are identified. For compensators, the maximum slopes in the machining process, which should not be exceeded, are quantified. For MLCs, emphasis is given to the direction perpendicular to leaf movement. A number of test modulations were created and the effect of different size MLCs on the intensity profile revealed that unacceptable errors can be introduced if the profiles are heavily modulated. The production of intensity modulated radiation therapy (IMRT) beams by both machined compensators or by MLCs is limited by physical constraints. Having identified these constraints, some steps should now be taken to accommodate them either in the objective function for the calculation of the beam profiles or in the delivery system.
Original languageEnglish
JournalBritish Journal of Radiology
Volume73
Issue number872
DOIs
Publication statusPublished - Aug 2000

Fingerprint

Radiotherapy
Direction compound

Bibliographical note

This article is not yet available on the repository.

Cite this

Some limitations in the practical delivery of intensity modulated radiation therapy. / Meyer, J.; Mills, J.A.; Haas, Olivier C.L.; Parvin, E.; Burnham, Keith J.

In: British Journal of Radiology, Vol. 73, No. 872, 08.2000.

Research output: Contribution to journalArticle

Meyer, J. ; Mills, J.A. ; Haas, Olivier C.L. ; Parvin, E. ; Burnham, Keith J. / Some limitations in the practical delivery of intensity modulated radiation therapy. In: British Journal of Radiology. 2000 ; Vol. 73, No. 872.
@article{6c05190eb519471cb16383b93f68de13,
title = "Some limitations in the practical delivery of intensity modulated radiation therapy",
abstract = "The resolution characteristics of intensity modulated beam (IMB) profiles produced by milled compensators and by multileaf collimators (MLCs) are independently investigated with respect to the primary fluence. It is shown that both methods have different characteristics in the longitudinal and lateral direction and, as a consequence, the resolutions of the longitudinal and lateral delivered IMB profiles differ. For both methods, the restrictions are identified. For compensators, the maximum slopes in the machining process, which should not be exceeded, are quantified. For MLCs, emphasis is given to the direction perpendicular to leaf movement. A number of test modulations were created and the effect of different size MLCs on the intensity profile revealed that unacceptable errors can be introduced if the profiles are heavily modulated. The production of intensity modulated radiation therapy (IMRT) beams by both machined compensators or by MLCs is limited by physical constraints. Having identified these constraints, some steps should now be taken to accommodate them either in the objective function for the calculation of the beam profiles or in the delivery system.",
author = "J. Meyer and J.A. Mills and Haas, {Olivier C.L.} and E. Parvin and Burnham, {Keith J.}",
note = "This article is not yet available on the repository.",
year = "2000",
month = "8",
doi = "10.1259/bjr.73.872.11026861",
language = "English",
volume = "73",
journal = "British Journal of Radiology",
issn = "0007-1285",
publisher = "British Institute of Radiology",
number = "872",

}

TY - JOUR

T1 - Some limitations in the practical delivery of intensity modulated radiation therapy

AU - Meyer, J.

AU - Mills, J.A.

AU - Haas, Olivier C.L.

AU - Parvin, E.

AU - Burnham, Keith J.

N1 - This article is not yet available on the repository.

PY - 2000/8

Y1 - 2000/8

N2 - The resolution characteristics of intensity modulated beam (IMB) profiles produced by milled compensators and by multileaf collimators (MLCs) are independently investigated with respect to the primary fluence. It is shown that both methods have different characteristics in the longitudinal and lateral direction and, as a consequence, the resolutions of the longitudinal and lateral delivered IMB profiles differ. For both methods, the restrictions are identified. For compensators, the maximum slopes in the machining process, which should not be exceeded, are quantified. For MLCs, emphasis is given to the direction perpendicular to leaf movement. A number of test modulations were created and the effect of different size MLCs on the intensity profile revealed that unacceptable errors can be introduced if the profiles are heavily modulated. The production of intensity modulated radiation therapy (IMRT) beams by both machined compensators or by MLCs is limited by physical constraints. Having identified these constraints, some steps should now be taken to accommodate them either in the objective function for the calculation of the beam profiles or in the delivery system.

AB - The resolution characteristics of intensity modulated beam (IMB) profiles produced by milled compensators and by multileaf collimators (MLCs) are independently investigated with respect to the primary fluence. It is shown that both methods have different characteristics in the longitudinal and lateral direction and, as a consequence, the resolutions of the longitudinal and lateral delivered IMB profiles differ. For both methods, the restrictions are identified. For compensators, the maximum slopes in the machining process, which should not be exceeded, are quantified. For MLCs, emphasis is given to the direction perpendicular to leaf movement. A number of test modulations were created and the effect of different size MLCs on the intensity profile revealed that unacceptable errors can be introduced if the profiles are heavily modulated. The production of intensity modulated radiation therapy (IMRT) beams by both machined compensators or by MLCs is limited by physical constraints. Having identified these constraints, some steps should now be taken to accommodate them either in the objective function for the calculation of the beam profiles or in the delivery system.

U2 - 10.1259/bjr.73.872.11026861

DO - 10.1259/bjr.73.872.11026861

M3 - Article

VL - 73

JO - British Journal of Radiology

JF - British Journal of Radiology

SN - 0007-1285

IS - 872

ER -