Abstract
Safety instrumented systems and emergency shutdown systems are extremely important for the management and reduction of risk in industry. New standards on functional safety of systems (e.g. [1]) often require a quantification of the achieved safety. Markov model has been known as a strong tool for modeling and evaluation of safety. In this article, we will provide a closed-form solution for computation of safety of parallel, standby, and NMR systems, given the reliability of these systems.
Original language | English |
---|---|
Title of host publication | Deterioration, Dependability, Diagnostics 2014 |
Place of Publication | Brno, Czech Republic |
Publisher | University of Defence |
Pages | 61–67 |
Number of pages | 7 |
ISBN (Print) | 978-80-7231-969-5 |
Publication status | Published - Oct 2014 |
Keywords
- Safety evaluation
- general solution
- parallel system
- standby system
- NMR system