Abstract
This paper provides a brief overview of recent developments in the field of self‐validating (SEVA) sensors. The fundamentals of SEVA are described, using the example of a dissolved oxygen sensor. UK standardisation activities are then discussed along with moves towards commercialisation. Finally, some recent research results based on a coriolis mass flow meter are presented.
Original language | English |
---|---|
Pages (from-to) | 16-22 |
Number of pages | 7 |
Journal | Sensor Review |
Volume | 21 |
Issue number | 1 |
DOIs | |
Publication status | Published - 1 Mar 2001 |
Externally published | Yes |
Keywords
- Sensors
- Fault analysis
- Fieldbus