Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation

Aizan Masdar, B. S.K.K. Ibrahim, Dirman Hanafi, M. Mahadi Abdul Jamil, K. A.A. Rahman

Research output: Chapter in Book/Report/Conference proceedingConference proceeding

9 Citations (Scopus)

Abstract

This paper focuses on developing a novel approach for measuring body joint angles, mainly the knee angles, for surface electrical stimulator system. In this work, we only focus on the sensing mechanism for measuring the knee joint angle using wearable sensors. Our system consists of multiple flex-sensors mounted on a supportive cloth and microelectromechanical systems (MEMS) vibratory gyroscope. In Body Sensor Network (BSN) field for medical purpose, body joint angle measurement system is quite important and useful for continuous monitoring in rehabilitation activities especially for Spinal Cord Injury (SCI) patients. Body joint angle measurement system is sensory type systems that provide information about angle movement of body joint. It is usually used at knee and arm joint to monitor the movement while patients do some exercises. This very important and helpful for the therapists and physicians in order to see the effectiveness of rehabilitations training. For knee angle movement evaluation, lower limb joint angles and segment angles were estimated by the Kalman filter from the data measured with wireless MEMS vibratory gyroscope and flex-sensors. Electrical stimulation was applied to the common peroneal nerve or the tibialis anterior muscle by detecting stimulus timing automatically from the data of wireless sensor attached at the back of knee which known as popliteal fossa and shank of the paraplegic side. The developed system performed well in monitoring the effectiveness of rehabilitations training with the knee joint angle measurement average error rate of 6.92°. The comparison between measured data of the gyroscope and flex-sensors for knee joint angle measurement system were also demonstrated.

Original languageEnglish
Title of host publicationBMEiCON 2013 - 6th Biomedical Engineering International Conference
PublisherIEEE
Number of pages4
ISBN (Electronic)9781479914678
DOIs
Publication statusPublished - 1 Dec 2013
Externally publishedYes
Event6th Biomedical Engineering International Conference - Krabi, Thailand
Duration: 23 Oct 201325 Oct 2013
http://www.bmeicon.org/download/CPFBMEICON2013.pdf

Publication series

NameBMEiCON 2013 - 6th Biomedical Engineering International Conference

Conference

Conference6th Biomedical Engineering International Conference
Abbreviated title BMEiCON 2013
CountryThailand
CityKrabi
Period23/10/1325/10/13
Internet address

Fingerprint

Gyroscopes
Angle measurement
Patient rehabilitation
Sensors
MEMS
Body sensor networks
Monitoring
Measurement errors
Kalman filters
Muscle

Keywords

  • flex-sensor
  • Functional electrical stimulation (FES)
  • gyroscope
  • knee joint angle

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Masdar, A., Ibrahim, B. S. K. K., Hanafi, D., Mahadi Abdul Jamil, M., & Rahman, K. A. A. (2013). Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation. In BMEiCON 2013 - 6th Biomedical Engineering International Conference [6687719] (BMEiCON 2013 - 6th Biomedical Engineering International Conference). IEEE. https://doi.org/10.1109/BMEiCon.2013.6687719

Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation. / Masdar, Aizan; Ibrahim, B. S.K.K.; Hanafi, Dirman; Mahadi Abdul Jamil, M.; Rahman, K. A.A.

BMEiCON 2013 - 6th Biomedical Engineering International Conference. IEEE, 2013. 6687719 (BMEiCON 2013 - 6th Biomedical Engineering International Conference).

Research output: Chapter in Book/Report/Conference proceedingConference proceeding

Masdar, A, Ibrahim, BSKK, Hanafi, D, Mahadi Abdul Jamil, M & Rahman, KAA 2013, Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation. in BMEiCON 2013 - 6th Biomedical Engineering International Conference., 6687719, BMEiCON 2013 - 6th Biomedical Engineering International Conference, IEEE, 6th Biomedical Engineering International Conference, Krabi, Thailand, 23/10/13. https://doi.org/10.1109/BMEiCon.2013.6687719
Masdar A, Ibrahim BSKK, Hanafi D, Mahadi Abdul Jamil M, Rahman KAA. Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation. In BMEiCON 2013 - 6th Biomedical Engineering International Conference. IEEE. 2013. 6687719. (BMEiCON 2013 - 6th Biomedical Engineering International Conference). https://doi.org/10.1109/BMEiCon.2013.6687719
Masdar, Aizan ; Ibrahim, B. S.K.K. ; Hanafi, Dirman ; Mahadi Abdul Jamil, M. ; Rahman, K. A.A. / Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation. BMEiCON 2013 - 6th Biomedical Engineering International Conference. IEEE, 2013. (BMEiCON 2013 - 6th Biomedical Engineering International Conference).
@inproceedings{38a86f23ffe944d3afd9d1a813604a88,
title = "Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation",
abstract = "This paper focuses on developing a novel approach for measuring body joint angles, mainly the knee angles, for surface electrical stimulator system. In this work, we only focus on the sensing mechanism for measuring the knee joint angle using wearable sensors. Our system consists of multiple flex-sensors mounted on a supportive cloth and microelectromechanical systems (MEMS) vibratory gyroscope. In Body Sensor Network (BSN) field for medical purpose, body joint angle measurement system is quite important and useful for continuous monitoring in rehabilitation activities especially for Spinal Cord Injury (SCI) patients. Body joint angle measurement system is sensory type systems that provide information about angle movement of body joint. It is usually used at knee and arm joint to monitor the movement while patients do some exercises. This very important and helpful for the therapists and physicians in order to see the effectiveness of rehabilitations training. For knee angle movement evaluation, lower limb joint angles and segment angles were estimated by the Kalman filter from the data measured with wireless MEMS vibratory gyroscope and flex-sensors. Electrical stimulation was applied to the common peroneal nerve or the tibialis anterior muscle by detecting stimulus timing automatically from the data of wireless sensor attached at the back of knee which known as popliteal fossa and shank of the paraplegic side. The developed system performed well in monitoring the effectiveness of rehabilitations training with the knee joint angle measurement average error rate of 6.92°. The comparison between measured data of the gyroscope and flex-sensors for knee joint angle measurement system were also demonstrated.",
keywords = "flex-sensor, Functional electrical stimulation (FES), gyroscope, knee joint angle",
author = "Aizan Masdar and Ibrahim, {B. S.K.K.} and Dirman Hanafi and {Mahadi Abdul Jamil}, M. and Rahman, {K. A.A.}",
year = "2013",
month = "12",
day = "1",
doi = "10.1109/BMEiCon.2013.6687719",
language = "English",
series = "BMEiCON 2013 - 6th Biomedical Engineering International Conference",
publisher = "IEEE",
booktitle = "BMEiCON 2013 - 6th Biomedical Engineering International Conference",

}

TY - GEN

T1 - Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation

AU - Masdar, Aizan

AU - Ibrahim, B. S.K.K.

AU - Hanafi, Dirman

AU - Mahadi Abdul Jamil, M.

AU - Rahman, K. A.A.

PY - 2013/12/1

Y1 - 2013/12/1

N2 - This paper focuses on developing a novel approach for measuring body joint angles, mainly the knee angles, for surface electrical stimulator system. In this work, we only focus on the sensing mechanism for measuring the knee joint angle using wearable sensors. Our system consists of multiple flex-sensors mounted on a supportive cloth and microelectromechanical systems (MEMS) vibratory gyroscope. In Body Sensor Network (BSN) field for medical purpose, body joint angle measurement system is quite important and useful for continuous monitoring in rehabilitation activities especially for Spinal Cord Injury (SCI) patients. Body joint angle measurement system is sensory type systems that provide information about angle movement of body joint. It is usually used at knee and arm joint to monitor the movement while patients do some exercises. This very important and helpful for the therapists and physicians in order to see the effectiveness of rehabilitations training. For knee angle movement evaluation, lower limb joint angles and segment angles were estimated by the Kalman filter from the data measured with wireless MEMS vibratory gyroscope and flex-sensors. Electrical stimulation was applied to the common peroneal nerve or the tibialis anterior muscle by detecting stimulus timing automatically from the data of wireless sensor attached at the back of knee which known as popliteal fossa and shank of the paraplegic side. The developed system performed well in monitoring the effectiveness of rehabilitations training with the knee joint angle measurement average error rate of 6.92°. The comparison between measured data of the gyroscope and flex-sensors for knee joint angle measurement system were also demonstrated.

AB - This paper focuses on developing a novel approach for measuring body joint angles, mainly the knee angles, for surface electrical stimulator system. In this work, we only focus on the sensing mechanism for measuring the knee joint angle using wearable sensors. Our system consists of multiple flex-sensors mounted on a supportive cloth and microelectromechanical systems (MEMS) vibratory gyroscope. In Body Sensor Network (BSN) field for medical purpose, body joint angle measurement system is quite important and useful for continuous monitoring in rehabilitation activities especially for Spinal Cord Injury (SCI) patients. Body joint angle measurement system is sensory type systems that provide information about angle movement of body joint. It is usually used at knee and arm joint to monitor the movement while patients do some exercises. This very important and helpful for the therapists and physicians in order to see the effectiveness of rehabilitations training. For knee angle movement evaluation, lower limb joint angles and segment angles were estimated by the Kalman filter from the data measured with wireless MEMS vibratory gyroscope and flex-sensors. Electrical stimulation was applied to the common peroneal nerve or the tibialis anterior muscle by detecting stimulus timing automatically from the data of wireless sensor attached at the back of knee which known as popliteal fossa and shank of the paraplegic side. The developed system performed well in monitoring the effectiveness of rehabilitations training with the knee joint angle measurement average error rate of 6.92°. The comparison between measured data of the gyroscope and flex-sensors for knee joint angle measurement system were also demonstrated.

KW - flex-sensor

KW - Functional electrical stimulation (FES)

KW - gyroscope

KW - knee joint angle

UR - http://www.scopus.com/inward/record.url?scp=84893246659&partnerID=8YFLogxK

U2 - 10.1109/BMEiCon.2013.6687719

DO - 10.1109/BMEiCon.2013.6687719

M3 - Conference proceeding

T3 - BMEiCON 2013 - 6th Biomedical Engineering International Conference

BT - BMEiCON 2013 - 6th Biomedical Engineering International Conference

PB - IEEE

ER -