Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system

T. Depuydt, D. Verellen, Olivier C.L. Haas, T. Gevaert, N. Linthout, M. Duchateau, K. Tournel, T. Reynders, K. Leysen, M. Hoogeman, G. Storme, M. De Ridder

    Research output: Contribution to journalArticle

    116 Citations (Scopus)
    Original languageEnglish
    Pages (from-to)365-372
    JournalRadiotherapy and Oncology
    Volume98
    Issue number3
    DOIs
    Publication statusPublished - Mar 2011

    Bibliographical note

    The full text of this item is not currently available from the repository.

    Keywords

    • real-time tumor tracking
    • tracking error
    • organ motion

    Cite this

    Depuydt, T., Verellen, D., Haas, O. C. L., Gevaert, T., Linthout, N., Duchateau, M., ... De Ridder, M. (2011). Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system. Radiotherapy and Oncology, 98(3), 365-372. https://doi.org/10.1016/j.radonc.2011.01.015

    Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system. / Depuydt, T.; Verellen, D.; Haas, Olivier C.L.; Gevaert, T.; Linthout, N.; Duchateau, M.; Tournel, K.; Reynders, T.; Leysen, K.; Hoogeman, M.; Storme, G.; De Ridder, M.

    In: Radiotherapy and Oncology, Vol. 98, No. 3, 03.2011, p. 365-372.

    Research output: Contribution to journalArticle

    Depuydt, T, Verellen, D, Haas, OCL, Gevaert, T, Linthout, N, Duchateau, M, Tournel, K, Reynders, T, Leysen, K, Hoogeman, M, Storme, G & De Ridder, M 2011, 'Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system' Radiotherapy and Oncology, vol. 98, no. 3, pp. 365-372. https://doi.org/10.1016/j.radonc.2011.01.015
    Depuydt, T. ; Verellen, D. ; Haas, Olivier C.L. ; Gevaert, T. ; Linthout, N. ; Duchateau, M. ; Tournel, K. ; Reynders, T. ; Leysen, K. ; Hoogeman, M. ; Storme, G. ; De Ridder, M. / Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system. In: Radiotherapy and Oncology. 2011 ; Vol. 98, No. 3. pp. 365-372.
    @article{7ac91de368244712a4b11c579d08fe0c,
    title = "Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system",
    keywords = "real-time tumor tracking, tracking error, organ motion",
    author = "T. Depuydt and D. Verellen and Haas, {Olivier C.L.} and T. Gevaert and N. Linthout and M. Duchateau and K. Tournel and T. Reynders and K. Leysen and M. Hoogeman and G. Storme and {De Ridder}, M.",
    note = "The full text of this item is not currently available from the repository.",
    year = "2011",
    month = "3",
    doi = "10.1016/j.radonc.2011.01.015",
    language = "English",
    volume = "98",
    pages = "365--372",
    journal = "Radiotherapy and Oncology",
    issn = "0167-8140",
    publisher = "Elsevier",
    number = "3",

    }

    TY - JOUR

    T1 - Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system

    AU - Depuydt, T.

    AU - Verellen, D.

    AU - Haas, Olivier C.L.

    AU - Gevaert, T.

    AU - Linthout, N.

    AU - Duchateau, M.

    AU - Tournel, K.

    AU - Reynders, T.

    AU - Leysen, K.

    AU - Hoogeman, M.

    AU - Storme, G.

    AU - De Ridder, M.

    N1 - The full text of this item is not currently available from the repository.

    PY - 2011/3

    Y1 - 2011/3

    KW - real-time tumor tracking

    KW - tracking error

    KW - organ motion

    U2 - 10.1016/j.radonc.2011.01.015

    DO - 10.1016/j.radonc.2011.01.015

    M3 - Article

    VL - 98

    SP - 365

    EP - 372

    JO - Radiotherapy and Oncology

    JF - Radiotherapy and Oncology

    SN - 0167-8140

    IS - 3

    ER -