Experimental study on buckling resistance of Guadua angustifolia bamboo column

Effendi Bahtiar, Dominika Malkowska, David Trujillo, Naresworo Nugroho

Research output: Contribution to journalArticlepeer-review

38 Citations (Scopus)
243 Downloads (Pure)

Abstract

An experimental study was conducted to evaluate the buckling behavior of 190 Guadua bamboo culms of various lengths. These were subjected to an axial compressive load until failure. The geometrical and physical properties of each culm were measured, as well as its compressive strength and load carrying capacity. The buckling reduction factor (ψ) – which is the ratio of the ultimate buckling load (Fcr) to the ultimate compressive load (Fu) or the ratio of the ultimate buckling stress (σcr) to the ultimate compressive stress (σu) – was determined for each specimen. Several formulas were investigated by means of linear and non-linear regression in order to find the best fit for ψ. Separate models for intermediate and long members, as well as models combining the whole range of the slenderness ratios (λ) were proposed. Rankine-Gordon’s and Ylinen’s buckling formulas proved to be suitable to determine the buckling reduction factor for the whole range of slenderness ratios for the Guadua bamboo specimens studied, whilst Euler’s formula is more appropriate for longer columns. For the intermediate columns, the Newlin-Gahagan’s buckling formula was initially evaluated; however it was deemed unsuitable due to its unsatisfactory statistical performance. As a replacement, the Johnson buckling formula was derived. Ylinen’s buckling formula appears to provide the best fit and it is therefore recommended for Guadua column design. A maximum slenderness ratio was calculated at the ψ = 0.057, which resulted in a slenderness ratios of 139, 214, and 161, when calculated by Rankine-Gordon’s, Ylinen’s, and Euler’s buckling formula, respectively. Those ratios are approximately equivalent to 43, 67, and 50 length to diameter ratios (L/D). Since Ylinen’s equation is the best fit buckling formula among others, it is recommended that the length does not exceed 67 times the diameter (L/D < 67). When the buckling reduction factor is used in combination with characteristic value, the load carrying capacity of a column of any length can be safely used in design of Guadua bamboo culms.
Original languageEnglish
Article number111548
Number of pages15
JournalEngineering Structures
Volume228
Early online date3 Dec 2020
DOIs
Publication statusPublished - 1 Feb 2021

Bibliographical note

NOTICE: this is the author’s version of a work that was accepted for publication in Engineering Structures. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Engineering Structures, 228, (2021) DOI: 10.1016/j.engstruct.2020.111548

© 2021, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/

Keywords

  • Bamboo
  • Buckling
  • Column member
  • Compression
  • Guadua
  • Regression
  • Structural
  • Structural design

ASJC Scopus subject areas

  • Civil and Structural Engineering

Fingerprint

Dive into the research topics of 'Experimental study on buckling resistance of Guadua angustifolia bamboo column'. Together they form a unique fingerprint.

Cite this