TY - JOUR
T1 - Comparison of cardiac output determined by different rebreathing methods at rest and at peak exercise
AU - Jakovljevic, DG
AU - Nunan, D
AU - Donovan, G
AU - Hodges, LD
AU - Sandercock, GR
AU - Brodie, DA
PY - 2008/3
Y1 - 2008/3
N2 - Several rebreathing methods are available for cardiac output (Q T) measurement. The aims of this study were threefold: first, to compare values for resting Q T produced by the equilibrium-CO2, exponential-CO2 and inert gas-N2O rebreathing methods and, second, to evaluate the reproducibility of these three methods at rest. The third aim was to assess the agreement between estimates of peak exercise Q T derived from the exponential and inert gas rebreathing methods. A total of 18 healthy subjects visited the exercise laboratory on different days. Repeated measures of Q T, measured in a seated position, were separated by a 5 min rest period. Twelve participants performed an incremental exercise test to determine peak oxygen consumption. Two more exercise tests were used to measure Q T at peak exercise using the exponential and inert gas rebreathing methods. The exponential method produced significantly higher estimates at rest (averaging 10.9 l min−1) compared with the equilibrium method (averaging 6.6 l min−1) and the inert gas rebreathing method (averaging 5.1 l min−1; P < 0.01). All methods were highly reproducible with the exponential method having the largest coefficient of variation (5.3%). At peak exercise, there were non-significant differences between the exponential and inert gas rebreathing methods (P = 0.14). The limits of agreement were −0.49 to 0.79 l min−1. Due to the ability to evaluate the degree of gas mixing and to estimate intra-pulmonary shunt, we believe that the inert gas rebreathing method has the potential to measure Q T more precisely than either of the CO2 rebreathing methods used in this study. At peak exercise, the exponential and inert gas rebreathing methods both showed acceptable limits of agreement.
AB - Several rebreathing methods are available for cardiac output (Q T) measurement. The aims of this study were threefold: first, to compare values for resting Q T produced by the equilibrium-CO2, exponential-CO2 and inert gas-N2O rebreathing methods and, second, to evaluate the reproducibility of these three methods at rest. The third aim was to assess the agreement between estimates of peak exercise Q T derived from the exponential and inert gas rebreathing methods. A total of 18 healthy subjects visited the exercise laboratory on different days. Repeated measures of Q T, measured in a seated position, were separated by a 5 min rest period. Twelve participants performed an incremental exercise test to determine peak oxygen consumption. Two more exercise tests were used to measure Q T at peak exercise using the exponential and inert gas rebreathing methods. The exponential method produced significantly higher estimates at rest (averaging 10.9 l min−1) compared with the equilibrium method (averaging 6.6 l min−1) and the inert gas rebreathing method (averaging 5.1 l min−1; P < 0.01). All methods were highly reproducible with the exponential method having the largest coefficient of variation (5.3%). At peak exercise, there were non-significant differences between the exponential and inert gas rebreathing methods (P = 0.14). The limits of agreement were −0.49 to 0.79 l min−1. Due to the ability to evaluate the degree of gas mixing and to estimate intra-pulmonary shunt, we believe that the inert gas rebreathing method has the potential to measure Q T more precisely than either of the CO2 rebreathing methods used in this study. At peak exercise, the exponential and inert gas rebreathing methods both showed acceptable limits of agreement.
KW - Cardiac output
KW - Measurement
KW - Rebreathing methods
KW - Healthy adults
UR - http://europepmc.org/abstract/med/18074146
UR - https://www.scopus.com/pages/publications/38649131971
U2 - 10.1007/s00421-007-0631-4
DO - 10.1007/s00421-007-0631-4
M3 - Article
C2 - 18074146
SN - 1439-6319
VL - 102
SP - 593
EP - 599
JO - European Journal of Applied Physiology
JF - European Journal of Applied Physiology
ER -