Advancing PPG signal quality and know-how through knowledge translation - from experts to student and researcher

Samuel Huthart, Moe Elgendi, Dingchang Zheng, Gerard Stansby, John Allen

    Research output: Contribution to journalArticlepeer-review

    19 Citations (Scopus)
    69 Downloads (Pure)

    Abstract

    Objective: Despite the vast number of photoplethysmography (PPG) research publications and growing demands for such sensing in Digital and Wearable Health platforms, there appears little published on signal quality expectations for morphological pulse analysis. Aim: to determine a consensus regarding the minimum number of undistorted i.e., diagnostic quality pulses required, as well as a threshold proportion of noisy beats for recording rejection. Approach: Questionnaire distributed to international fellow researchers in skin contact PPG measurements on signal quality expectations and associated factors concerning recording length, expected artifact-free pulses (“diagnostic quality”) in a trace, proportion of trace having artifact to justify excluding/repeating measurements, minimum beats required, and number of respiratory cycles. Main Results: 18 (of 26) PPG researchers responded. Modal range estimates considered a 2-min recording time as target for morphological analysis. Respondents expected a recording to have 86–95% of diagnostic quality pulses, at least 11–20 sequential pulses of diagnostic quality and advocated a 26–50% noise threshold for recording rejection. There were broader responses found for the required number of undistorted beats (although a modal range of 51–60 beats for both finger and toe sites was indicated). Significance: For morphological PPG pulse wave analysis recording acceptability was indicated if <50% of beats have artifact and preferably that a minimum of 50 non-distorted PPG pulses are present (with at least 11–20 sequential) to be of diagnostic quality. Estimates from this knowledge transfer exercise should help inform students and researchers as a guide in standards development for PPG study design.
    Original languageEnglish
    Article number619692
    Number of pages7
    JournalFrontiers in Digital Health
    Volume2
    DOIs
    Publication statusPublished - 21 Dec 2020

    Bibliographical note

    Copyright © 2020 Huthart, Elgendi, Zheng, Stansby and Allen. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

    Keywords

    • digital health
    • photoplethysmography
    • pulse
    • peripheral arterial disease
    • pulse wave analysis
    • signal quality
    • wearable sensor
    • artefact rejection

    Fingerprint

    Dive into the research topics of 'Advancing PPG signal quality and know-how through knowledge translation - from experts to student and researcher'. Together they form a unique fingerprint.

    Cite this