Abstract
This paper presents a novel methodology for the detection and diagnosis of rotor faults in induction machines using signal estimation. The proposed approach is independent of the motor slip and relies on the isolation of main harmonics rather than on the investigation of signatures with traditional approaches such as the identification of fault-related sidebands. The method is applied on the stator line current capturing the transient nature of fault-related frequencies at the steady state. Thus, it enables a reliable diagnostic strategy by the isolated harmonics and their analysis over time and frequency. The method's effectiveness was explored with electromagnetic simulations of two induction machines of different geometry, manufacture, and power scale. Then, the method was validated experimentally on a 1.1 kW induction motor.
| Original language | English |
|---|---|
| Pages (from-to) | 6129-6139 |
| Number of pages | 11 |
| Journal | IEEE Transactions on Industry Applications |
| Volume | 61 |
| Issue number | 4 |
| Early online date | 24 Feb 2025 |
| DOIs | |
| Publication status | Published - 2025 |
Keywords
- harmonic isolation
- induction motors
- rotor faults
ASJC Scopus subject areas
- Control and Systems Engineering
- Industrial and Manufacturing Engineering
- Electrical and Electronic Engineering